  • Development of domestic inverter automation system

    Development of domestic inverter automation system

    With the increasingly high degree of systematization and integration of automation applications in various industries, the demand of users for the overall solution of the industry is increasingly prominent, and the inverter industry is in urgent need of change. When the customer's experience requirements are higher and higher, the simple use of frequency converter can no longer meet the needs of customers.
  • The difference between

    The difference between "braking" and "stopping" of frequency converter

    One form is called "free parking.". As the name implies, it is to quickly "power off" the motor, so that the motor can slide and stop by its own inertia force (off2 stop);
  • The basic characteristics of frequency converter drive are different from that of power frequency power supply

    The basic characteristics of frequency converter drive are different from that of power frequency power supply

    Compared with the motor driven by sine wave, the power factor and efficiency of the motor will be deteriorated and the temperature rise will increase due to the influence of high harmonics in the output waveform of the inverter. When the frequency converter drives, the output current of the frequency converter should be equal to that of the fundamental power supply.
  • How to deal with jumping out overload signal when frequency converter drives motor

    How to deal with jumping out overload signal when frequency converter drives motor

    Mechanical overload: the main feature of overload is motor heating, and can be found by reading the running current from the display screen. The main reasons are that the load of frequency converter is too large, the acceleration and deceleration time and the operation cycle time are too short; the voltage of V / F characteristic is too high; the power of frequency converter is too small.
  • Frequency converter output harmonic test harmonic parameters fluctuate greatly, what is the reason?

    Frequency converter output harmonic test harmonic parameters fluctuate greatly, what is the reason?

    The switching frequency of traction motor inverter is relatively low, and its switching frequency is often not an integral multiple of fundamental frequency. In this way, the inverter output is not strictly periodic signal (of course, there is no strict periodic signal in the objective world, which means that the error is large). For example, each signal cycle contains 8.2 switching pulses.
  • Solution to the influence of frequency converter on motor

    Solution to the influence of frequency converter on motor

    Variable frequency drive (VFD) is a kind of power control equipment which uses frequency conversion technology and microelectronics technology to control AC motor by changing the frequency mode of motor power supply.
  • The difference between frequency converter and servo

    The difference between frequency converter and servo

    The basic concept of servo is accurate, accurate and fast positioning. Frequency conversion is a necessary internal link of servo control, and there is also frequency conversion (stepless speed regulation) in servo driver. But the servo will current loop speed loop or position loop closed control, this is a big difference. In addition, the structure of the servo motor is different from that of the ordinary motor
  • When is it necessary to consider increasing the capacity of the inverter?

    When is it necessary to consider increasing the capacity of the inverter?

    As mentioned above, when the rated current of some inverters is less than the rated current of motors of the same capacity, a larger inverter should be selected according to the load of the motor.
  • The normal selection and capacity matching of frequency converter is actually very important!

    The normal selection and capacity matching of frequency converter is actually very important!

    When selecting frequency converter, the actual motor current value should be taken as the basis of frequency converter selection, and the rated power of motor can only be used as reference. Second, the frequency converter and high-order power factor will be considered.
  • Treatment of undervoltage fault in inverter maintenance

    Treatment of undervoltage fault in inverter maintenance

  • Several problems to be considered in changing frequency converter to servo

    Several problems to be considered in changing frequency converter to servo

    There are essential differences between servo and inverter in purpose and function. Which one to choose depends on the operating mode, load conditions, price and other factors. Basically, the performance of servo is superior to that of frequency converter. Therefore, when the inverter is changed to servo, there will be no operation problems. However, the following points must be considered.
  • How is the leakage of motor using frequency converter?

    How is the leakage of motor using frequency converter?

    The inverter output is controlled by PWM (pulse width modulation, similar to high-speed switch), so leakage current with high frequency will occur.
  • Four control methods of frequency converter to motor

    Four control methods of frequency converter to motor

    U/f constant control U/f control is to change the voltage of the motor power supply while changing the frequency of the motor power supply to keep the motor magnetic flux constant. In a wide range of speed regulation, the efficiency and power factor of the motor do not drop. Because it is the ratio of control voltage (Voltage) to frequency (Frequency), it is called U/f control.
  • Inverter and soft start, you choose wrong!

    Inverter and soft start, you choose wrong!

    Soft starter and frequency converter are two completely different products. Frequency converter is used in the place where speed regulation is needed, its output not only changes the voltage but also changes the frequency; the soft starter is actually a voltage regulator
  • What are the load characteristics of frequency converter

    What are the load characteristics of frequency converter

    The correct selection of frequency converter is very important for the normal operation of control system. When selecting frequency converter, we must fully understand the load characteristics driven by frequency converter. In practice, production machinery is often divided into three types: constant torque load, constant power load, fan and pump load.
  • How to judge the quality of a frequency converter?

    How to judge the quality of a frequency converter?

    At present, the performance of domestic inverters is becoming more and more mature, with a wide range of types, which dazzles the candidates, Many brands have been tested by the market, but some brands have been imitated to disturb the market. One of the characteristics of domestic brands is that the appearance of a domestic brand is similar to that of an imported brand, and that of a domestic
  • Does the frequency converter affect the motor

    Does the frequency converter affect the motor

    Ordinary asynchronous motors are designed according to constant frequency and constant voltage, which can not fully meet the requirements of variable frequency speed regulation. The following is the influence of frequency converter on motor:
  • Influence of inverter working environment

    Influence of inverter working environment

    In the practical application of frequency converter, in addition to a small number of domestic customers have special machine rooms, most of them install the frequency converter directly on the industrial site in order to reduce the cost. There are problems of dust, high temperature and high humidity in the work site, such as metal dust and corrosive gas in aluminum industry
  • What is the difference between general inverter and vector converter

    What is the difference between general inverter and vector converter

    I believe that we have been in contact with the frequency converter, and many friends have used it. There are two kinds of frequency converters: general frequency converter and vector frequency converter. Although both of them can be used, there are differences between them. After reading the analysis below, we can understand why the price of vector converter is higher than that of general inverter.
  • Why DC mode is preferred in the middle link of frequency converter?

    Why DC mode is preferred in the middle link of frequency converter?

1 2 3 4 5 6 7
3/7

QR code

The public,

Mobile station
The public, Mobile station

Contact

未標(biāo)題-8.png 0755-81719517
未標(biāo)題-10.png0755-81719530 未標(biāo)題-11.pngamb@ambition.com.cn
未標(biāo)題-12.pngFloor 1, 5 and 6, building 7, lijincheng science and technology industrial park, gongye dong road, longhua new district, shenzhen

Navigation

Home          About

Product      Case

Solution      Service

Job      News

Contact          

Copyright © Shenzhen Ambition Electronic Co., Ltd Record number:備案號(hào):粵ICP備12045920號(hào)
主站蜘蛛池模板: 长江有色金属 | 久久久亚洲一区二区三区 | 日韩欧美第一区 | 超碰成人影院 | 黑人与日本少妇高潮 | amazon亚马逊欧洲站 | 免费成人黄动漫视频 | 国产激情视频在线观看的 | 国产又色又爽又黄的A片 | 最近日本字幕免费高清 | 中文av字幕在线 | 国产亚洲精品麻豆一区二区 | 嫩草官网视频入口 | a在线视频v视频 | A片免费观看一区二区三区 欧美aaaa视频 | 免费一级欧美片在线观看网站 | 天堂av8在线| 国产一区二区三区四区无人区 | AV不卡秒播在线观看 | 久久99精品久久久久麻豆 | 午夜激情在线观看视频 | 国产精品久久久久久久久久蜜臀 | 亚洲精品无码久久久久苍井空国产一 | 日韩三级免费看 | 美女很黄免费 | 少妇无码太爽了不卡白浆 | 狠狠干av | 欧美 日韩 国产 一区 | 国产精品免费无遮挡无码永久视频 | 欧美性色欧美a在线图片 | 他也色在线视频 | 天堂在线最新资源 | 黄色成人在线看 | 国产精品丝袜一区二区 | 极品福利视频 | 手机在线永久免费观看av片 | 亚洲成人aa | 国产第7页| 欧美精品第一页 | 国产艳视频 | 久久大伊人 |